North-Seeking IMU FSS-NS2

Introduction Domestic leading MEMS IMU north finder
Volume R28.8x330.5mm
Weight 427g
Application field Tunnel exploration survey, underground pipe network mapping, tunnel / underground north finding
Product features Ultra high precision gyroscope, ultra-high and low noise, stable operation in full temperature range
Software interface TTL; CAN
Hardware interface Customized interface
86-15148215714
DetailTechnical IndexDownloadHardware and Structu

MEMS IMU North Seeking

North seeking accuracy: 0.25 ° ( 1σ )

Ultra High Precision Gyroscope

Bias instability: 0.17°/h

Ultra Low Noise

Low Noise Beyond Fiber Optic Gyro

Ultra Small Volume

Size of 28.8 x 330.5 mm

Full Temperature Stable Operation

Steady Fine Temperature Compensation at -40~85 ℃

Flexible Working Interface

On-demand customization such as SPI/I²C/Serial/CAN

Gyroscope Key Metrics

Parameters

Test Conditions/Remarks

Min.

Typ.

Max.

Unit

Measurement Range



±500


°/s

Bias Instability X-axis

@25℃, ALLAN Variance, 1σ


1.10


°/hr

Bias Instability Y-axis

(North-finding Axis)


0.17


°/hr

Bias Instability Z-axis

(North-finding Axis)


0.17


°/hr

Misalignment



0.05


deg

Internal Low-pass Cutoff Frequency

Adjustable Software


47


Hz

ODR



100


Hz

Measure Delay




7.0

ms

Random Walk¹

@25℃, ALLAN Variance, 1σ


0.015


°/√hr

Scale Coefficient Error



1.0


Note 1: IEEE standard values acquired from Allan Variance analysis in a static environment (25°C)


Accelerometer Key Metrics

Parameters

Test Conditions/Remarks

Min.

Typ.

Max.

Unit

Measurement Range



±6


g

Bias Instability

@25℃, ALLAN Variance, 1σ


3


μg

Misalignment



0.05


deg

Internal Low-pass Cutoff Frequency

Adjustable Software


47


Hz

ODR



100


Hz

Measure Delay




7.0

ms

Random Walk¹

@25℃, ALLAN Variance, 1σ


0.005


m/s/√hr